• 2220E
  • Model number 2220E
    Description Thru-hole mount 360℃ cable orientation Lightweight
    Sensitivity pC/g typical 3.0
    Sinusoidal limit g 1,000
    Shock limit g 5000
    Frequency response ±5%,Hz 1 to 12,000
    Operating Temperature ℃ -55 to +260 (-67 to +500)
    Signal/ground isolation Yes
    Hermetic seal Yes
    Weight grams(without cable) 3.1
    Dimensions mm (in) ? 9.53 x 5.8 (? 0.375 x 0.23)
    Mounting method Screw
    Cable included 3053V-120
  • 2221F
  • Model number 2221F
    Description Thru-hole mount 360℃ cable orientation
    Sensitivity pC/g typical 10
    Sinusoidal limit g 1,000
    Shock limit g 3000
    Frequency response ±5%,Hz 0.1-12,000
    Operating Temperature ℃ -55 to +260 (-67 to +500)
    Signal/ground isolation Yes
    Hermetic seal Yes
    Weight grams(without cable) 11
    Dimensions mm (in) ? 15.24 x 8.9 (? 0.60 x 0.35)
    Mounting method Screw
    Cable included 3090C-120
  • 2230E
  • Model number 2230E
    Description Triaxial Adhesive mount
    Sensitivity pC/g typical 3
    Sinusoidal limit g 1,000
    Shock limit g 2000
    Frequency response ±5%,Hz 1-10,000
    Operating Temperature ℃ -55 to +260 (-67 to +500)
    Signal/ground isolation No
    Hermetic seal Yes
    Weight grams(without cable) 17
    Dimensions mm (in) 17.15 x 11.68 x 15.24 (0.675 x 0.46 x 0.60)
    Mounting method Adhesive
    Cable included 3053V-120(3)
  • 2230EM1
  • Model number 2230EM1
    Description Triaxial Flange mount
    Sensitivity pC/g typical 3
    Sinusoidal limit g 1,000
    Shock limit g 2000
    Frequency response ±5%,Hz 1-10,000
    Operating Temperature ℃ -55 to +260 (-67 to +500)
    Signal/ground isolation No
    Hermetic seal Yes
    Weight grams(without cable) 22.5
    Dimensions mm (in) 17.15 x 11.68 x 15.24 (0.675 x 0.46 x 0.60)
    Mounting method Screw
    Cable included 3053V-120(3)
  • 62225
  • Model number 62225
    Description ARINC mount Differential output
    Sensitivity pC/g typical 20/50/100
    Sinusoidal limit g 2000/1000500
    Shock limit g 4000/2000/1000
    Frequency response ±5%,Hz 1-12,000/1-9000/1-9000
    Operating Temperature ℃ -54 to +260 (-65 to +500)
    Signal/ground isolation Yes
    Hermetic seal Yes
    Weight grams(without cable) 91
    Dimensions mm (in) 41.4 x 30.2 x 20.3 (1.63 x 1.19 x 0.80)
    Mounting method Screw
    Cable included No
  • 7240C
  • Model number 7240C
    Description Very high frequency
    Sensitivity pC/g typical 3.0
    Sinusoidal limit g 1000
    Shock limit g 5000
    Frequency response ±5%,Hz 1-20,000
    Operating Temperature ℃ -55 to +260 (-67 to +500)
    Signal/ground isolation No
    Hermetic seal Yes
    Weight grams(without cable) 4.8
    Dimensions mm (in) 9.53 hex x 11.68 (3/8 hex x 0.46)
    Mounting method Stud
    Cable included 3053V-120
  • 7201
  • Model number 7201
    Description General purpose
    Sensitivity pC/g typical 10/50/100
    Sinusoidal limit g 2000
    Shock limit g 20,000/10,000/5000
    Frequency response ±5%,Hz 1-15,000/1-10,000/1-8000
    Operating Temperature ℃ -73 to +260 (-100 to +500)
    Signal/ground isolation No
    Hermetic seal Yes
    Weight grams(without cable) 18/20/25
    Dimensions mm (in) 15.88 hex x 19.8 (5/8 hex x 0.78)
    Mounting method Stud
    Cable included 3090C-120
  • 7703A
  • Model number 7703A
    Description General Purpose Radiation tested
    Sensitivity pC/g typical 50/100/200/300/1000
    Sinusoidal limit g 2000/1000/850/675/500
    Shock limit g 10,000/5000/2000/1600/1000
    Frequency response ±5%,Hz 1-9000/1-8000/1-6000/ 1-5000/1-3000
    Operating Temperature ℃ -55 to +288 (-67 to +550)
    Signal/ground isolation Yes
    Hermetic seal Yes
    Weight grams(without cable) 25/29/62/70/120
    Dimensions mm (in) for -50/-100 : 16.0 hex x 19.8 (5/8hex x 0.78) for -200/-300/-1000 : 25.4 hex x 23.1 (1.0 hex x 0.91)
    Mounting method Stud
    Cable included 3090C-120
  • 7704A
  • Model number 7704A
    Description General Purpose Radiation tested
    Sensitivity pC/g typical 50/100
    Sinusoidal limit g 2000/1000
    Shock limit g 10,000/5000
    Frequency response ±5%,Hz 1-9000/1-8000
    Operating Temperature ℃ -55 to +288 (-67 to +550)
    Signal/ground isolation Yes
    Hermetic seal Yes
    Weight grams(without cable) 25/29
    Dimensions mm (in) 16.0 hex x 21.1 (5/8 hex x 0.83)
    Mounting method Stud
    Cable included 3090C-120
  • 25A
  • Model number 25A
    Description Ultra miniature
    Sensitivity pC/g typical 5
    Linear range g ±740
    Shock limit g 2000
    Frequency response ±5%,Hz 1-12,000
    Broadband noise (㎍ rms) 7000
    Operating temperature℃(℉) -55 to +125 (-67 to +257)
    Signal/ground isolation Yes
    Hermetic seal No
    Weight grams(without cable) 0.2
    Dimensions mm (in) ? 0.381 x 2.54 (? 0.15 x 0.10)
    Mounting method Adhesive
    Cable included Integral with 3024-120